Vici 450 Dynacalibrator Bedienungsanleitung Seite 1

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Messgeräte Vici 450 Dynacalibrator herunter. VICI 450 Dynacalibrator User Manual [ru] Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 44
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Valco Instruments Co. Inc.
Rev 9/13
Dynacalibrator
Model 450
Instruction Manual
Valco Instruments Co. Inc.
800 · 367· 8424 sales
713
· 688· 9345 tech
713
· 688· 8106 fax
VICI AG International
Schenkon, Switzerland
Int + 41
· 41 · 925· 6200 phone
Int + 41
· 41 · 925· 6201 fax
North America, South America, and Australia/Oceania contact: Europe, Asia, and Africa contact::
Manufactured by:
Valco Instruments Co. Inc.
8300 Waterbury
Houston, TX 77055
Seitenansicht 0
1 2 3 4 5 6 ... 43 44

Inhaltsverzeichnis

Seite 1 - Instruction Manual

Valco Instruments Co. Inc. Rev 9/13 Dynacalibrator Model 450 Instruction ManualValco Instruments Co. Inc.800 · 367· 8424 sales 713 · 688· 9345 tech 7

Seite 2 - Symbols used in this document

6calibration output of the cali brator to the inlet port of each of the analyzers. The calibrator chamber may contain two permeation devices with dif

Seite 3 - Table of Contents

7SpecificationsIntroduction

Seite 4

8Getting StartedEvery Dynacalibrator is completely calibrated, thoroughly tested and inspected, and carefully packed prior to shipment. The carrier ha

Seite 5 - Introduction

9Getting StartedConcealed DamageConcealed damage is damage which is not apparent until after the equipment has been unpacked and examined or tested. I

Seite 6

10Unit LocationIn general, the Dynacalibrator should be as close as possible to the analyzer to be calibrated, as long as:• theambienttemperaturei

Seite 7

11Rear Panel ConnectionsRemove all shipping caps and shipping plugs from the rear panel bulkhead fit-tings. All these hardware items should be saved f

Seite 8

12Supply InletAll Dynacalibrators except those with -1X input configurations (separate carrier and dilution inlet ports) are equipped with a supply inl

Seite 9

13so a source of pressurized gas must be connected to its carrier inlet and its dilution inlet. On the remaining three input configurations, these inl

Seite 10 - Special Customer Options

14Front Panel Controls and IndicatorsThe section entitled “Advanced Theory of Operation” beginning on page 27 includes more detailed information on t

Seite 11 - Specifications

15SHUTDOWN30° 120°.15.10.05CHAMBERFLOWMODE CONTROLREMOTESPAN 1ZERODYNACALIBRATORMODEL 450PERMEATION CHAMBERLOCKTEMPERATURE °CPNL TMPSE

Seite 12 - Getting Started

AttentionRadiant heat warningEntanglement warningElectrical warningSymbols used in this document

Seite 13 - Concealed Damage

16CalculationsConcentration of the permeant compound in the span outlet stream is inversely proportional to the carrier flow rate through the chamber.

Seite 14 - Unit Location

17Initial Power-UpConnections1. Connect a 24 VDC power source to the rear panel power input connector. (We offer a suitable power supply as an optio

Seite 15 - Rear Panel Connections

18Setting the Chamber Temperature ManuallyTo read the current set point: press and hold the button. To read the chassis environment temperature: p

Seite 16 - Carrier/Dilution Inlets

19Setting the Chamber Temperature via Serial Port (RS-232)Refer to the section titled “Serial Port Communications” on page 20.Installing the Permeatio

Seite 17 - Overflow Vent

20Serial Port CommunicationThe temperature of the Dynacalibrator Model 450 can be monitored and controlled remotely by means of a serial port DB-9 fe

Seite 18

212. Click “Cancel”. Since no modem is involved, this information is not necessary. The following screen will appear:3. Click “OK”, which reveals

Seite 19 - DYNACALIBRATOR

226. Select the appropriate COM port and click “OK” to bring up this screen:7. Set the port parameters as indicated above, and click “OK”.8. Now we

Seite 20 - Calculations

239. On the dyna450 Properties screen (above), click “Settings” to bring up the screen below. Click “Settings”Click “ASCII Setup...”Serial Port Commu

Seite 21 - Initial Power-Up

2410. Click “ASCII Setup” and set the parameters as indicated below. Click “OK”.11. When the screen returns to Dyna450 HyperTerminal (page 22, botto

Seite 22

25Analyzer CalibrationAfter the power-up procedure has been com pleted and the chamber temp-erature and permeation device have reached equilibrium, th

Seite 23

Table of ContentsIntroduction General Description...

Seite 24 - Serial Port Communication

26Shutdown ProcedureDynacalibrators are designed to operate continuously; however, if it is necessary to turn the unit off, use the following procedur

Seite 25

27Figure 8: Basic block diagramAdva

Seite 26

28this number to indicate the carrier flow (and the orifice used). Refer to page 4 for information about the available flow capacity ranges.Many of the

Seite 27

29Configuration 2Pump P1 (Figure 11) draws gas in through the supply inlet on the back panel and delivers it to accumulator AC1. The accumulator smoot

Seite 28 - Entering Commands

30

Seite 29 - Analyzer Calibration

31Configuration 5in this configuration (Figure 14), pump P1 draws gas in through the supply inlet on the back panel and delivers it to accumulator AC1.

Seite 30 - Shutdown Procedure

32 Electrical DescriptionThe basic wiring of the Model 450 is shown schematically in Figure 15. Dynacali-brators are powered from a benchtop style tr

Seite 31 - Advanced Theory of Operation

33MaintenanceSince Dynacalibrators are designed for and generally used in applications that require continuous service, a planned routine maintenance

Seite 32 - Configuration 1

349. Inspect all assembly mountings for loose hardware, and tighten as necessary.10. Rinse the fan screen and fan filter in clean water and blow dry

Seite 33 - Configuration 4

35MaintenanceChamber Temperature CalibrationPrior to shipment, the permeation chamber digital temperature control is calibrated against the temperatu

Seite 34

Table of Contents (continued) Advanced Theory of Operation ...

Seite 35 - Configuration 5

36TroubleshootingIf you intend to perform detailed troubleshooting on your Dynacalibrator, please first read the section entitled “Advanced Theory of

Seite 36 - Electrical Description

37TroubleshootingPneumatic TroubleshootingThere are two reasonably direct methods that can be used to troubleshoot leaks in a Dynacalibrator, each wi

Seite 37 - Maintenance

38Troubleshooting3. Starting at the air source end of the suspect loop, break a fitting and, using an appropriate adapter, connect the leak checker ga

Seite 38 - Carrier Flow Rate Verification

39Model Number Breakdown

Seite 39

40WarrantyThis Limited Warranty gives the Buyer specific legal rights, and a Buyer may also have other rights that vary from state to state. For a per

Seite 40 - Troubleshooting

1IntroductionGeneral DescriptionVICI Metronics Dynacalibrators® use Dynacal® permeation devices to generate the precise gas concentrations necessary f

Seite 41 - Pneumatic Troubleshooting

2IntroductionAs indicated in Figure 1, the carrier stream passes through scrubber #1 and micron line filter LF1 to the differential pres sure regulator

Seite 42

3IntroductionWhen the calibrator mode is changed to ZERO, SPAN 1, or SPAN 2 – either by remote command or the mode selector switch – SV3 energizes to

Seite 43 - Model Number Breakdown

4Figure 2 summarizes the Model 450 output flow configurations. When the mode selector switch is in the REMOTE po sition with no remote inputs, the cali

Seite 44 - Warranty

5Remote monitoring station450 DynacalibratorGas analyzerRemote control panelSpan 1ZeroRemoteSampleinletStreamoutletSpan 1StandbyZeroRecorderSpan 2Stan

Verwandte Modelle: Dynacalibrator 450

Kommentare zu diesen Handbüchern

Keine Kommentare