Dynacalibrator
Model 340
Instruction Manual
Valco Instruments Co. Inc.
800 · 367· 8424 sales
713
· 688· 9345 tech
713
· 688· 8106 fax
VICI AG International
Schenkon, Switzerland
Int + 41
· 41 · 925· 6200 phone
Int + 41
· 41 · 925· 6201 fax
North America, South America, and Australia/Oceania contact: Europe, Asia, and Africa contact::
Manufactured by:
Valco Instruments Co. Inc.
8300 Waterbury
Houston, TX 77055
Seitenansicht 0
1 2 3 4 5 6 ... 43 44

Inhaltsverzeichnis

Seite 1 - Instruction Manual

Valco Instruments Co. Inc. Rev 9/13 Dynacalibrator Model 340 Instruction ManualValco Instruments Co. Inc.800 · 367· 8424 sales 713 · 688· 9345 tech

Seite 2 - Symbols used in this document

6Getting StartedEvery Dynacalibrator is completely calibrated, thoroughly tested and inspected, and carefully packed prior to shipment. The carrier ha

Seite 3 - Table of Contents

7Concealed DamageConcealed damage is damage which is not apparent until after the equipment has been unpacked and examined or tested. In the event tha

Seite 4

8Unit LocationIn general, the Dynacalibrator should be as close as possible to the analyzer to be calibrated, as long as:• theambienttemperatureis

Seite 5 - Introduction

9Rear Panel ConnectionsRemove all shipping caps and shipping plugs from the rear panel bulkhead fittings. All these hardware items should be saved fo

Seite 6

10On all units with an internal pump, the supply inlet port is internally connected directly to the suction side of the pump. Since the output of the

Seite 7

11Bypass LoopsOnly those Dynacalibrators with internal pumps are equipped with fittings for bypass loops in either or both the carrier and dilution str

Seite 8 - Special Customer Options

12Front Panel Controls and IndicatorsThe section entitled “Advanced Theory of Operation” beginning on page 27 includes more detailed information on t

Seite 9 - Specifications

13 

Seite 10 - Getting Started

14CalculationsConcentration of the permeant compound in the span outlet stream is inversely proportional to the carrier flow rate through the chamber.

Seite 11 - Concealed Damage

15Initial Power-UpBasic Connections1. Plug the power cable from the main power connector on the rear panel of the calibrator to a 110 VAC power source

Seite 12 - Unit Location

AttentionRadiant heat warningEntanglement warningElectrical warningSymbols used in this document

Seite 13 - Rear Panel Connections

16The front panel displays the current chamber temperature and the control status of the instrument, indicated by the PNL and TMP lights. (Refer to F

Seite 14 - Carrier/Dilution Inlets

17Setting the Chamber Temperature via Serial Port (RS-232)Refer to the section titled “Serial Port Communications” on page 20.Installing the Permeatio

Seite 15 - Bypass Loops

18Verifying Operation1. Connect a piece of tubing of the proper length to the span outlet fitting on the rear panel, leaving the analyzer end of the tu

Seite 16

199. Check that there is gas flow out of the overflow vent and the stream outlet, but not out of the chamber vent.10. If remote control will be used,

Seite 17 - 

20Serial Port CommunicationThe Dynacalibrator Model 340 can be monitored and controlled remotely by means of a serial port connection and a terminal e

Seite 18 - Calculations

212. Click “Cancel”. Since no modem is involved, this information is not necessary. The following screen will appear:3. Click “OK”, which reveals

Seite 19 - Initial Power-Up

226. Select the appropriate COM port and click “OK” to bring up this screen:7. Set the port parameters as indicated above, and click “OK”.8. Now we

Seite 20

239. On the dyna340 Properties screen (above), click “Settings” to bring up the screen below. Click “Settings”Click “ASCII Setup...”Serial Port Commu

Seite 21

2410. Click “ASCII Setup” and set the parameters as indicated below. Click “OK”.11. When the screen returns to Dyna340 HyperTerminal (page 22, botto

Seite 22 - Verifying Operation

25Analyzer CalibrationAfter the power-up procedure has been completed and the chamber tempera-ture and permeation device have reached equilibrium, the

Seite 23

Table of ContentsIntroductionGeneral Description...

Seite 24 - Serial Port Communication

26Shutdown ProcedureDynacalibrators are designed to operate continuously; however, if it is necessary to turn the unit off, use the following procedur

Seite 25

27Advanced Theory of OperationDynacalibrator operation is based on the principle of mixing a known mass flow of gas derived from a permeation device wi

Seite 26

28this number to indicate the carrier flow (and the orifice used). Refer to page 4 for information about the available flow capacity ranges.Many of the

Seite 27

29Configuration 2Pump P1 (Figure 7) draws gas in through the supply inlet on the back panel and delivers it to accumulator AC1. The accumulator smoothe

Seite 28 - Entering Commands

30Advanced Theory of Operation©§

Seite 29 - Analyzer Calibration

31Configuration 5in this configuration (Figure 10), pump P1 draws gas in through the supply inlet on the back panel and delivers it to accumulator AC1.

Seite 30 - Shutdown Procedure

32 Electrical DescriptionThe basic wiring of the Model 340 is shown schematically in Figure 11. Dynacali-brators are powered from a benchtop style tr

Seite 31 - Advanced Theory of Operation

33MaintenanceSince the Dynacalibrators are designed for and generally used in applications that require continuous service, a planned routine maintena

Seite 32 - Configuration 1

349. Inspect all assembly mountings for loose hardware, and tighten as necessary.10. Rinse the fan screen and fan filter in clean water and blow dry

Seite 33 - Configuration 4

35Chamber Temperature CalibrationPrior to shipment, the permeation chamber digital temperature control is calibrated against the temperature of the g

Seite 34

Table of Contents (continued) Advanced Theory of Operation ...

Seite 35 - Configuration 5

36TroubleshootingIf you intend to perform detailed troubleshooting on your Dynacalibrator, please first read the section entitled “Advanced Theory of O

Seite 36 - Electrical Description

37Troubleshooting4. Isolate the leak by using a small quantity of leak detection fluid on each possible leak point in the suspect loop. Watch carefu

Seite 37 - Maintenance

38Troubleshooting7. Once a section of the loop has been deter mined to be leak free, go to the next fitting downstream of the point of the previous c

Seite 38 - Carrier Flow Rate Verification

39Model Number Breakdown

Seite 39

40WarrantyThis Limited Warranty gives the Buyer specific legal rights, and a Buyer may also have other rights that vary from state to state. For a peri

Seite 40 - Troubleshooting

1IntroductionGeneral DescriptionVICI Metronics Dynacalibrators® use Dynacal® permeation devices to generate the precise gas concentrations necessary f

Seite 41

2IntroductionAs indicated in Figure 1, the carrier stream passes through scrubber #1 and 30-micron line filter LF1 to the differential pres sure regul

Seite 42 - Other Pneumatic Issues

3IntroductionThe flow rate through the flowmeter needle valve is a function of the differential pressure across it and the setting of the dilution flow c

Seite 43 - Model Number Breakdown

4IntroductionOptionsThe following paragraphs provide general information on each, with more detailed information found in “Advanced Theory of Operati

Seite 44 - Warranty

5Specifications